In This Article we are going to discuss about SIEMENS Weather station sensor device overview.

 

sensor
Weather Sensor

Use :

  • Weather station with sensors to survey Temperature, Brightness, Rain and Wind Speed as well as integrated GPS module.
  • Temperature, wind and rain sensors.
  • Three integrated brightness sensors each 90° apart
  • GPS positioning
  • Easy mast installation with attached mast bracket.


Function:

  • Functions with commissioning with ETS
  • Sending of the current GPS coordinates
  • Two objects for external brightness sensors
  • Adjustment of slats position according to current sun position
  • Sun protection area both horizontal and vertical
  • Sun protection can be temporarily interrupted via object
  • Sensor evaluation with logical AND/ OR operation of the measurement readings
  • Threshold switches with delay when falling below and exceeding
  • Logic modules with four input objects independent of the measurement readings


Features

  • These devices are weather stations with integrated brightness, temperature and wind sensors to detect meteorological data. 
  • The weather station AP 257/61 GPS contains also a rain sensor and an integrated GPS module. 
  • The devices communicate via KNX. 
  • The devices are designed for outdoor installation at buildings.

SIEMENS Weather station sensor device
Contents 1



weather sensor
Contents 2


Usage :

The main application is the measurement and processing of meteorological data to control venetian blinds, roller shutters or awnings.


Temperature sensor :

The integrated temperature sensor detects the current temperature value.


Wind sensor :

The integrated wind sensor detects the current wind speed. To be able to detect the real wind speed it is recommended to install the devices on a mast, especially for facades exposed to strong frontal winds.


 Rain sensor

The integrated rain sensor detects precipitation.


Brightness sensors

Three integrated brightness sensors detect, independent of each other, the current brightness. It is possible to use the average of the three sensors for further proceeding.


GPS module

The integrated GPS module detects the GPS coordinates (longitude and latitude) of the location as well as current date and time.


Functions with configuration with ETS :

The relevant sensors for evaluation of the meteorological data and the further proceeding can be set via ETS.


Functions of the weather station :

  • The weather station contains four independent functional blocks (evaluation units).
  •  According to the settings different telegrams can be sent via the KNX bus. 
  • The values of the communication objects are set via parameters for each functional block (sensor evaluation, facade, threshold switch, logic module) separately. 


Technology and  Model

sensor element


Location / Function of the Display and Operating Elements

1. rain sensor with heating (AP 257/61 only)

2. three brightness sensors (front, right and left)

3. programming button and LED

4. wind wheel

5. temperature sensor

6. wall fixation with connection for 24 Volt DC SELV (AP 257/61 model only) and bus connection (KNX)

 

Mounting

  • The devices are designed for outdoor installation at buildings. 
  • They can be mounted directly at the façade of the building.
  • Alternatively they can also be installed on a mast or at an edge of the facade, both by using the mast bracket.
  • At first weather station and wall fixation must be separated. 
  • For folding up the device (2) respectively for dismounting the wall fixation (5), it is sufficient to loosen the corresponding screws (1), (3). 
mounting
Mounting 1

  • Afterwards the wall fixation and the mast bracket, if applicable, can be mounted at the building respectively at the mast. 
mounting
Mounting 2

  • After the weather station has been connected (see following section “Connection”), it has to be slipped onto the wall fixation again.
SIEMENS Weather station sensor device
Mounting 3

Weather station sensor
Mounting 4



SIEMENS Weather station sensor device
Mounting 5




 
Note:

  • The wind sensor should not be installed at a sheltered position.
  • Shadows (example from masts) and reflected light should be avoided.
  • The weather station only works in correct mounting position (wind rotor at the bottom).


 

Connection

connection
Connection 1


  • To connect the devices to the bus respectively the 24 Volt  power supply (AP 257/61 model only) the cables have to be fed through the rubber seals provided, which have been pierced with a suitable tool before. 
  • It is important that the hole is not too big, to ensure tightness. 
  • Then the cables have to be plugged into the screw less terminal respectively the bus terminal. 
  • Correct polarity has to be ensured.

SIEMENS Weather station sensor device
Connection 2



Note:

  • The DC 24 Volt output voltage of the Power Supply Unit N 125/x2 must not be used as power supply for the weather station.

Commissioning

weather sensor
Commissioning

  • The programming button at the bottom of the device is pressed with a screwdriver to receive the physical address. 
  • The programming LED is on. 
  • It turns off automatically after receiving the physical address.


 

Technical data

Physical Specifications

Housing is plastic

Weight is approximate  300 gram based on the model

Fire load is  approximate  12 MJ

Colour is transparent.


  • Power supply is via KNX 15 to 34 Volt DC SELV (for heating of rain sensor, AP 257/61 model only)
  • Bus current is less than 10 milliamps - AP 257/51 and based on the other models Bus current is varied.
  • Power loss type is maximum  0.24 Watt at 24 Volt DC - AP 257/51 model and based on the other models Power loss  is varied.


Range of sensors :

Sensor Brightness is 1 to 100.000 luminous flux.

Wind speed is 2 to 30 m/s

Temperature is minus 30 to plus 60 °C

Status rain sensor is rain/ no rain.

Control elements  is 1 Programming button for load physical address.

Display elements is 1 LED for monitoring bus voltage and for displaying normal mode or addressing Mode

 

Connections :

KNX BUS
KNX BUS

KNX  bus terminal is  diameter 0.6 to 0.8 mm, strip insulation is  5 to 6 mm

24 Volt DC SELV (AP 257/61 model only) is screw less terminal, 0.5 to 1.5 mm2, strip insulation is 5 to 6 mm

 

Environmental conditions :

Ambient temperature in operation is minus 20 °C to plus 55 °C

Storage temperature is minus 20 °C to plus 70 °C    

Relative humidity (non-condensing) is 5 % to 93 %

Climatic withstand capability is EN 50428

Protection class EN 60529 is IP44

 

Sensor evaluation

The sensor evaluation contains ten independent channels, each of it with two telegrams.

Each sensor evaluation can be used for subtasks (example. brightness threshold) or for any combination of measurement values.

Each sensor evaluation contains up to 4 weather conditions, linked via a logical operation:

  1. Brightness below or above threshold
  2. Temperature below or above threshold
  3. Wind speed below or above threshold
  4. It rains or it doesn’t rain (AP 257/61 only)

  • The weather conditions can be linked via a logical AND or a logical OR. 
  • An irrelevant condition (example temperature) can be omitted and will not be considered by the logical operation.
  • It can be defined which telegram should be sent if the AND respectively OR condition is met or is not met. If necessary a second telegram could be sent.
  • If required, a sensor evaluation can also be defined as safety channel, when the relevant values, that is temperature, rain and wind are linked via a logical OR. 
  • The result of this logical operation can be used as safety message, if the parameters for the “facades” are set accordingly.